29.08.2008

WinCON 8000 series - W 8347 / W 8747

New Hot-Swap and Redundant Solution for the WinCON-8347 / WinCON-8747.
To meet the requirement of the tough industrial application, IPC2U group present the new Hot-Swap and redundant solution for the WinCON W-8347 / W-8747 . This redundant system has always setup two Active IP address points to the active W-8x47's LAN1 and LAN2 ports. One or two or more PC / HMI / SCADA can communicate with this redundant system via one of the two given active IP. So the PC / HMI / SCADA can have access to the system easily without any notice, on which W-8x47 is currently active. Moreover, the new redundant system could be intergarte with the RU-87P4 and RU-87P8 expansion unit plus the I-87K high-profile I/O cards to support the Hot-Swap application. If any I/O card is damaged, the maintenance person just takes one good-card with same model name to Hot-Swap the damaged one without stopping this redundant system..



WinCON W-8347 - System-Charakteristika

Lexcom Systems Neo

Abb.: WinCON W-8347

W-8347-G
Information:

  • ISaGRAF PAC
  • CPU Speed / 206MHz
  • Embedded OS / Windows CE.NET
  • Slot / 3
  • Flash / 32 Mbyte
  • SDRAM / 64 Mbyte
  • Peripherals / 2x Ethernet Port, 1x VGA Port, 2x CF Slot, 2x USB, 1x RS-232, 1x RS-485


WinCON W 8747 - System-Charakteristika

Lexcom Systems Neo

Abb.: WinCON W-8747

W-8747-G
Information:

  • ISaGRAF PAC
  • CPU Speed / 206MHz
  • Embedded OS / Windows CE.NET
  • Slot / 7
  • Flash / 32 Mbyte
  • SDRAM / 64 Mbyte
  • Peripherals / 2x Ethernet Port, 1x VGA Port, 2x CF Slot, 2x USB, 1x RS-232, 1x RS-485


The system contains two WinCON W-8347 or two WinCON W-8747 , plus two NS-205 / NS-208 (Industrial Ethernet Switch), and at least one RU-87P4 or RU-87P8 expansion base plus at least one I-87K high-profile I/O card. One W-8x47 is named as Main PAC, the other is called the Backup PAC. The Main PAC takes the control in normal case and its LAN1 and LAN2 IP are automatically changed to the Active_IP1 and Active_IP2. If it is damaged, the Backup PAC will take the control and also change to the Active_IP1 and Active_IP2 automatically. So the PC / HMI don't care about which one is active, and just connects continuously.


WinConn

Features:

  1. Controller is redundant
  2. Ethernet is redundant
  3. I/O is Hot-Swap



Order Informations

Please contact your IPC2U representative or sales@ipc2U.de for further information.